Biztonsági ajánlások a
2005/015 számú eseményhez |
Kategória: |
Serious incident |
Esemény helye, ideje: |
Praga, Czech Republic, 2005.01.31. 18:40 |
A légijármű típusa: |
BOEING - 737-600 |
Lajstromjel: |
HA-LOJ |
Üzembentartó: |
Hungary - Malev - Hungarian Airlines |
Kivizsgálás hatásköre |
POLÉBISZ |
Az esemény leírása
While deicing at PRG with engines running the crew switched off the engines and APU bleeds. After the deicing procedure the engine bleeds remained in off position and the aircraft took off with this pressuration system configuration. At FL 100 the intermittent horn was sounded. At FL 130 the oxigen masks came out. At Fl 150 the crew stopped climbing and declaired emergency. The crew noticed the engine bleeds switches were in off position and they switched them on. Thereafter the air pressuration system started to work normally, the crew withdraw emergency and continued its flight to BUD. |
Biztonsági ajánlások: - |
Biztonsági intézkedések: - |
|